How do I fix a backup error?

A back-up error is caused by either a dead battery or by the changing of one of the DIP switches located on the SCU card.  All the preset data for ALL (8) work selects must be programmed in order to clear this fault.
Enter data for all 8 work select (3 pages each(fastening, limits, speed pages) for each work select) even if you are only using one work select.  Use the "WORK INC" key to increment the work select page.  The work select page number is displayed in the upper right hand corner during DATA SET mode.  You may just hit the "Enter" key on the pages you are not using.  This will enter the data into memory.  Once all work select pages have been entered, the screen will change to "Data Setting" then the normal screen will appear.

 

 