My System's Abnormal LED is lit. How do I find out what the abnormal was without the AFC Software?
The Axis Unit can display an abnormal
code when the display unit is attached to the Axis Unit. The
Code will indicate the cause of the abnormal condition. From section 7.1.3 of the
manual.
FASTENING PRESET / RESULT DISPLAYS.
- [D-NO] Data number indicator (2
digits).
Indicates the Display mode and data
type by number.
- [DATA] Data value indicator (4
digits).
Displays the current torque value of
the torque transducer while in the real-time indication mode. Displays
the data specified by [D-NO] while in the fastening data indication
mode.
- [PARM] Parameter number/abnormal
number indicator (2 digits).
Display for the parameter number of the
last fastening. Also indicates if an abnormal condition occurs. When the
CAL switch is pressed, "E" is shown if the FULL-SCALE preset
value is missing or a wrong tool is connected (Refer to Chapter
9).
 From section 9.1 of the manual.
ABNORMAL CONDITIONS
When an abnormal condition is detected by
the system, it halts and lights the ABNORMAL LED. For ease of
troubleshooting the nature of the abnormal, the system provides an
abnormal code in the [PARM] display and an abnormal sub-code in the
[DATA-NO] display.
When an Abnormal condition occurs
(ABNORMAL LED is lit), go to the STATUS mode by depress the [MODE] key
several times until a blinking "A" appears in the [PARM]
display. A code number appears at the right side of the blinking
character. This code refers to some specific type of failure detailed in
the tables shown in the following sections.
- Abnormal Sub-code display.
The number shown at the most right
position is a sub-code that can be used in conjunction with the Abnormal
failure code to further narrow down the cause of the fault. See the
following sections.

| The main Abnormal
codes are: |
|
ABNORMAL CODE |
DESCRIPTION |
|
1 |
Torque transducer failure. |
|
2 |
Over torque error. |
|
3 |
Tool EEPROM error. |
|
4 |
Flash ROM error. |
|
5 |
Servo amplifier reply error. |
|
6 |
Servo type mismatch error. |
|
7 |
Internal power supply error. |
|
8 |
Servo amplifier error. |
|
9 |
Parameter error. |
| Abnormal sub-codes
and specific actions for troubleshooting are detailed in the
following section. (Refer to Chapter
9). |