Search  

 

 

 

Related Links

Operation Manuals

 

DSP1500

 

 

 

Enforce Servo Presses use only 1 - 3% of the electric power of standard hydraulic presses!!
(more)

 

 

 

 

 

Easily Adapts

Press Controllers

SAN3 PRESS CONTROLLER

Three controller models cover the full range of press sizes.  As a result of miniaturized circuit technology, the compact units maintain a maximum width of 123.5mm (largest model) in spite of the built in power source and servo amplifier.  All 3 controllers are back panel mountable and feature the following:

  • Isolated Gate Bipolar Technology (IGBT)
  • Fully Digital System (eliminates analog potentiometers)
  • 32 different work parameters (part programs) that can be stored into Flash ROM.  No battery backup required.
  • External communication is available through (2) RS-485 ports.  Connecting a group of up to 31 press controllers is also possible through this port when communicating using the DSP User Console Software.
  • A hot-swappable Display Module is available for viewing result data and can be used to program individual controllers.  The RS-232 version can output single press ASCII data to a serial device.

 

SAN Unit

SAN3-24S (M)

SAN3-40S (M)

SAN3-120S (M)

Motor Models

RM1

RM2

RM3

RM4H

RM5

Motor Power

60W

80W

200W

1500W

3000W

SAN Input Power

180-242VAC, 3ø , 50/60Hz.

SAN Inrush Current

18A

38.6A

116.4A

SAN Power Idle

18W

18W

18W

In Cycle*

23W/hr

88W/hr

107W/hr

134W/hr

(M) designation on SAN part number signifies for use with Main Unit
* In cycle power measured @97% Capacity, 99% Stroke, 60% duty

 

MAIN UNIT CONTROLLER

The Main Unit is a complimentary controller device to enhance the DSP1500 capabilities by providing the data communication and sequence control features for single and multiple (up to 31) press applications. The use of the Main Unit reduces valuable engineering, start-up and debug time by allowing full sequencing functionality & press data to be handled independently of an outside controller (PLC).  Additionally, all Input / Output functions are assumed by the Main Unit for all connected presses while also allowing use of a multiple of standard Fieldbus Interfaces. 

Optional fieldbus capabilities for:
Ethernet I/P, Allen Bradley Remote I/O®, DeviceNet®, Interbus-S®, Profibus®, CC-Link® and Modbus Plus® are available eliminating hard wired I/O thus reducing debug & start-up costs.  Additionally, Ethernet I/P, CC-Link® & DeviceNet® technologies allow transfer of resultant press data across the same communication link as the I/O.

Main Unit Specification
(Part # DSPMAIN2-xx)

Input Power

100 - 242VAC Single Phase 50/60Hz

Power Consumption

9 watts/hr

Dimensions (H x D x W)

265mm x 160mm x 70mm

Main Unit I/O Interface Part Number adder (Add dash number "-xx" to end of Main Part Number)
  -1 = Discrete I/O (24Vdc Sink Type)
  -2 = Discrete I/O (24Vdc Source Type)
  -6 = Allen Bradley Remote I/O
  -9 = DeviceNet
  -8 = Modbus Plus
-10 = Ethernet I/P
-11 = Interbus-S
-12 = CCLink V2
-13 = Profibus
-14 = CCLink